BCSCP - RED STENCIL INK 7081
- MSDS: BCSCP
- Manufacturer: CROWN INDUSTRIAL PRODUCTS CO INC
- Product Name: RED STENCIL INK 7081
- National Stock Number: 7510-00N009310
Product Identification
Product ID:RED STENCIL INK 7081
MSDS Date:02/04/1986
FSC:7510
NIIN:00N009310
MSDS Number: BCSCP
Responsible Party
HEBRON, IL 60034
Emergency Phone: 815-648-2424
Info Phone: 815-648-2424
Preparer: ROBERT E. BAYTON
Cage: 92381
Contractor
Telephone: 815-648-2424
Cage: 92381
Ingredients
ACETONE (SARA III)
CAS: 67-64-1
RTECS: AL3150000
Fraction By Weight: 31-50%
OSHA PEL 1000PPM
ACGIH TLV: 750PPM/1000STEL;9293
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
METHYLENE CHLORIDE (SARA III)
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 31-50%
OSHA PEL 500 PPM/C,1000; Z2
ACGIH TLV: 50 PPM, A2; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
LIQUIFIED PETROLEUM GAS, SWEETENED
CAS: 68476-86-8
Fraction By Weight: 11-30%
XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 1-10%
OSHA PEL 100 PPM/150 STEL
ACGIH TLV: 100 PPM/150STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 31-50%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS & SYMPTOMS OF OVEREXPOSURE.
Explanation of Carcinogenicity:ACGIH SUSPECTED HUMAN CARCINOGEN
Effects of Overexposure:INHAL HIGH VAPOR CONCENTRATIONS MAY RESULT IN
DIZZINESS HEADACHES OR UNCONSCIOUSNESS. INGEST NOT LIKELY EYE:MAY
CAUSE IRRITATION POSSIBLE CORNEAL INJURY.SKIN:PROLONGED CONTACT
WILL CAUSE DEFATTING OF SKIN LEADING TO IRRITATION & DERMATITIS.
Medical Cond Aggravated by Exposure:MAY INCREASE MYOCARDIAL
IRRITABILITY AVOID EPINEPHRINE OR SIMILAR DRUGS IF AT ALL POSSIBLE.
First Aid
First Aid:CALL A PHYSICIAN. EYE FLUSH WITH WATER FOR 15 MINUTES OR
UNTIL IRRITATION SUBSIDES.SKIN:REMOVE ALL CONTAMINATED
CLOTHING.INHAL:EWMOVE FROM EXPOSURE IMMEDIATELY.IF BREATHING IS
IRREGULAR OR STOPPED STA RT ARTIFICIAL RESP. & ADMINISTER O*2.
INGEST:DO NOT INDUCE VOMITING DRINK PLENTY OF WATER.
Fire Fighting
Flash Point Method:TCC
Flash Point:(SEE SUP DATA)
Lower Limits:1.8
Upper Limits:9.5
Extinguishing Media:CARBON DIOXIDE DRY CHEMICAL,FOAM
Fire Fighting Procedures:WEAR PRESSURE DEMAND SCBA AND FULL PROTECTIVE
EQUIPMENT
Unusual Fire/Explosion Hazard:TREAT AS CYLINDERS OF COMPRESSED GAS.
THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL & PHOSGENE
Accidental Release
Spill Release Procedures:VENT. AREA REMOVE ALL SOURCES OF IGNITION.
CLEAN UP WITH INERT MATERIALS & DISPOSE OF IN ACCORDANCE WITH ALL
LOCAL STATE & FEDERAL REGULATIONS.
Handling
Handling and Storage Precautions:DO NOT STORE IN DIRECT SUNLIGHT OR
TEMP ABOVE 120F. DO NOT SMOKE WHILE SPRAYING.
Other Precautions:NO SMOKING IN AREA OF USE,DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING.OPEN FLAMES OR HOT SURFACES, HEAT &/OR UV
RADIATION MAY CAUSE THE FORMATION OF HCL &/OR PHOSGENE .
Exposure Controls
Respiratory Protection:RESPIRATORY PROTECTION SHOULD BE IN ACCORDANCE
WITH 29 CFR 1910.134. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN
Ventilation:LOCAL EXHAUST IS ADEQUATE.
Protective Gloves:POLYETHYLENE OR NEOPRENE
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING & EQUIPMENT.
Work Hygienic Practices:WASH SKIN WITH SOAP & H*20
Supplemental Safety and Health
FL PT:AEROSOL CONTAINER <20F--6.6C.1
Chemical Properties
Vapor Pres:45-S0PIG
Vapor Density:>1
Spec Gravity:>1
pH:
Evaporation Rate & Reference:<1 ETHER=1
Solubility in Water:NEG
Appearance and Odor:RED/ETHEREAL ODOR
Percent Volatiles by Volume:90+5.0
Corrosion Rate:
Stability
Stability Indicator/Materials to Avoid:YES
ALKALI METALS,MINERAL ACIDS.
Stability Condition to Avoid:OPEN FLAMES,SPARKS ELECTRICAL SPARK
SOURCES
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY YIELD SMALL
AMOUNTS OF HALOGEN ACIDS,CARBON MONOXIDE,& OTHER TOXIC
CHEMICALS:HCL,PHOSGENE
Disposal
Waste Disposal Methods:DO NOT PUNCTURE OR INCINERATE.EMPTY CONTAINERS
MAY BE DISPOSED OF THROUGH NORMA CHANNELS.FULL OR PARTIALLY FILLED
CONTAINERS ARE CONSIDERED HAZARDOUS WASTE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.